• 15 wire insulation types — added TFFN and the full fixture-wire family (PF, PGF, PAF, PTF, ZF, SF-1, SF-2, RFH-2, FFH-2, KF-1) plus high-temperature FEP, FEPB, PFA, PFAH, TFE
• Added 16 AWG and 18 AWG sizes for fixture wire
• Nipple mode: nipples up to 24 in fill to 60% (NEC Chapter 9, Note 4)
• Auto-suggests the smallest conduit that fits — even when the current size passes
• Bug fixes and stability improvements
Send feedback to support@tradetools.dev.
Description
NEC conduit fill calculator for electricians, apprentices, and electrical engineers. Calculate conduit fill percentages instantly using official NEC Chapter 9 data - Tables 1, 4, and 5. This electrical raceway calculator supports all conduit types and wire sizes. Works 100% offline on the job site.
Whether you're pulling THHN through EMT, running FMC to a motor, or sizing PVC for a big commercial run, this conduit fill calculator gives you accurate NEC-compliant results in seconds. Use it as your portable conduit fill chart and raceway fill reference, faster than looking up wire count tables manually - perfect for residential and commercial installations.
CONDUIT FILL CALCULATOR FEATURES:
- 13 conduit types: EMT, ENT, FMC, IMC, LFNC-A, LFNC-B, LFMC, RMC, PVC Schedule 40, PVC Schedule 80, PVC Type A, PVC Type EB, HDPE
- Trade sizes from 3/8" through 6"
- 15 wire insulation types: building wire (THHN/THWN-2, XHHW-2, THW, RHH/RHW-2, USE-2, TW), fixture wire (TFFN/TFN, PF, PGF, PAF, PTF, ZF, SF-1, SF-2, RFH-2, FFH-2, KF-1) and high-temperature FEP, FEPB, PFA, PFAH, TFE
- Wire sizes: 18 AWG to 1000 MCM (16/18 AWG for fixture wire)
- AWG and mm² (metric) wire display
- NEC Table 1 fill rules: 53% (1 wire), 31% (2 wires), 40% (3+ wires)
- Visual PASS/FAIL indicator with fill percentage
- Shows how many more wires you can add
- Auto-suggests the smallest conduit size that fits your wires - even when the current size already passes
- Nipple mode: conduit nipples up to 24 in use the NEC 60% fill allowance (Chapter 9, Note 4)
- Mix different wire sizes in the same conduit fill calculation
PRO FEATURES (one-time purchase):
- No ads - clean interface for professionals
- Save conduit fill calculation history
- Export calculations as PDF reports for permits and records
- Dark theme support
BUILT FOR ELECTRICIANS ON THE JOB SITE:
This conduit fill calculator is designed by electricians, for electricians. The interface is clean, fast, and works with one hand. Add wires, see your fill percentage, and move on - no complicated menus or unnecessary features.
ACCURATE NEC CONDUIT FILL DATA:
All conduit and wire areas are sourced from the NEC Chapter 9. Conduit fill percentages follow NEC Table 1 rules exactly:
- 1 wire: 53% maximum fill
- 2 wires: 31% maximum fill
- 3 or more wires: 40% maximum fill
NEC TABLES INCLUDED:
- NEC Chapter 9, Table 1 - Percent fill for conduit and tubing
- NEC Chapter 9, Table 4 - Conduit dimensions and areas (EMT, ENT, FMC, IMC, LFNC, LFMC, RMC, PVC, HDPE)
- NEC Chapter 9, Table 5 - Wire dimensions and areas (THHN, XHHW, THW, RHW, USE, TW, TFFN, PF, ZF, SF, RFH, KF, FEP, PFA, TFE)
PERFECT FOR:
- Licensed electricians doing conduit fill calculations daily
- Electrical apprentices studying for journeyman exams
- Electrical engineers and designers
- Electrical contractors bidding commercial and residential jobs
- NEC code exam preparation
- Anyone who needs a fast, accurate conduit fill calculator
- Conduit sizing and wire count on the job site
OFFLINE & PRIVACY:
- Works 100% offline - no internet needed on the job site
- No account required
- No data collection - your calculations stay on your device
Simplify your conduit fill calculations on the job site.
In-App Purchases ZM pricing
One-Time Purchases
Pro Unlock—
Capabilities
In-App Purchases
Accessibility
ipadiphonemacrealityDevicetvoswatch
Version history 7 versions
Build 886924010v1.2.02026-06-13 23:25:15
What's new:
• 15 wire insulation types — added TFFN and the full fixture-wire family (PF, PGF, PAF, PTF, ZF, SF-1, SF-2, RFH-2, FFH-2, KF-1) plus high-temperature FEP, FEPB, PFA, PFAH, TFE
• Added 16 AWG and 18 AWG sizes for fixture wire
• Nipple mode: nipples up to 24 in fill to 60% (NEC Chapter 9, Note 4)
• Auto-suggests the smallest conduit that fits — even when the current size passes
• Bug fixes and stability improvements
Send feedback to support@tradetools.dev.
Build 886817840v1.1.92026-06-11 19:19:57
What's new:
• AWG / mm² unit toggle in Settings — show wire sizes with their metric cross-section (e.g. 12 AWG · 3.31 mm²)
• Metric labels apply everywhere: wire picker, wire list, history and PDF export
• NEC fill math is unchanged — mm² is the exact area of the AWG/MCM conductor; conduit trade sizes stay as-is
• Bug fixes and stability improvements
Thanks for the suggestion in reviews! Send feedback to support@tradetools.dev.
Build 886755805v1.1.82026-06-10 14:10:47
What's new:
• Full NEC Chapter 9 Table 4 coverage — 13 conduit types, including FMC, ENT, LFMC, LFNC-A/B, PVC Type A, PVC Type EB and HDPE
• More wire insulation types: XHHW-2, THW, RHH/RHW-2, USE-2 and TW
• Trade sizes now range from 3/8" to 6"
• The size list adapts to the conduit and wire type you select
Thanks to everyone who asked for more conduit types — keep the feedback coming at support@tradetools.dev.
Build 885076104v1.1.72026-04-29 23:32:46
What's new:
• Moved to tradetools.dev — new umbrella site for all our trade calculators
• Updated support email: support@tradetools.dev
• Refreshed privacy & support pages with unified design
• Bug fixes and stability improvements
Thanks for using ElecTools! Send feedback to support@tradetools.dev.
Build 884947036v1.1.62026-04-26 17:56:40
Privacy & ad consent update:
- Updated ad consent flow to comply with Google AdMob's latest privacy requirements
- Added "Manage Ad Privacy" option in Settings so users in the EU and UK can review or change their consent at any time
- Improved ad initialization stability and App Tracking Transparency handling
- Minor performance and reliability fixes
Build 884918861v1.1.52026-04-25 21:42:56
Cross-promotion improvements: links to other Electools apps now open in App Store on iOS instead of Google Play.
Bug fixes and stability improvements.
Build 884287736v1.1.42026-04-23 07:55:11
Price history by region
Currency
Show
Columns
Search
Availability 30 of 30 storefronts
| Region | Language | Price | Ratings | Avg | Version |
|---|---|---|---|---|---|
AI | en-GB | USD 0.99 | 0 | — | 1.2.0 |
BN | en-GB | USD 0.99 | 0 | — | 1.2.0 |
BW | en-GB | USD 0.99 | 0 | — | 1.2.0 |
CL | es-MX | CLP 990 | 0 | — | 1.2.0 |
CN | zh-Hans-CN | CNY 8 | 0 | — | 1.2.0 |
CO | es-MX | COP 4900 | 0 | — | 1.2.0 |
CY | en-GB | EUR 0.99 | 0 | — | 1.2.0 |
DE | de-DE | EUR 0.99 | 0 | — | 1.2.0 |
EC | es-MX | USD 0.99 | 0 | — | 1.2.0 |
ES | es-ES | EUR 0.99 | 0 | — | 1.2.0 |
FR | fr-FR | EUR 0.99 | 0 | — | 1.2.0 |
HK | zh-Hant-HK | HKD 8 | 0 | — | 1.2.0 |
JP | ja | JPY 150 | 0 | — | 1.2.0 |
KE | en-GB | USD 0.99 | 0 | — | 1.2.0 |
KY | en-GB | USD 0.99 | 0 | — | 1.2.0 |
LC | en-GB | USD 0.99 | 0 | — | 1.2.0 |
MD | en-GB | USD 0.99 | 0 | — | 1.2.0 |
ME | en-GB | EUR 0.99 | 0 | — | 1.2.0 |
MO | zh-Hant-HK | USD 0.99 | 0 | — | 1.2.0 |
MT | en-GB | EUR 0.99 | 0 | — | 1.2.0 |
MU | en-GB | USD 0.99 | 0 | — | 1.2.0 |
MY | en-GB | MYR 4.9 | 0 | — | 1.2.0 |
PE | es-MX | PEN 4.9 | 0 | — | 1.2.0 |
PY | es-MX | USD 0.99 | 0 | — | 1.2.0 |
TW | zh-Hant-TW | TWD 30 | 0 | — | 1.2.0 |
US | en-US | USD 0.99 | 0 | — | 1.2.0 |
VC | en-GB | USD 0.99 | 0 | — | 1.2.0 |
VE | es-MX | USD 0.99 | 0 | — | 1.2.0 |
XK | en-GB | EUR 0.99 | 0 | — | 1.2.0 |
ZM | en-GB | USD 0.99 | 0 | — | 1.2.0 |
Change log 11 changes · ZM
✎
releaseNotes updated
What's new:
• 15 wire insulation types — added TFFN and the full fixture-wire family (PF, PGF, PAF, PTF, ZF, SF-1, SF-2, RFH-2, FFH-2, KF-1) plus high-temperatu
✎
description updated
NEC conduit fill calculator for electricians, apprentices, and electrical engineers. Calculate conduit fill percentages instantly using official NEC Chapter 9 d
✎
subtitle updated
NEC Chapter 9 Pipe Fill
✎
name updated
Conduit Fill Calculator-NEC
◆
Version 1.2.0 released
What's new:
• 15 wire insulation types — added TFFN and the full fixture-wire family (PF, PGF, PAF, PTF, ZF, SF-1, SF-2, RFH-2, FFH-2, KF-1) plus high-temperature FEP, FEPB, PFA, PFAH, TFE
• Added 16 AWG and 18 AWG sizes for fixture wire
•
◆
Version 1.1.9 released
What's new:
• AWG / mm² unit toggle in Settings — show wire sizes with their metric cross-section (e.g. 12 AWG · 3.31 mm²)
• Metric labels apply everywhere: wire picker, wire list, history and PDF export
• NEC fill math is unchanged — mm² i
◆
Version 1.1.8 released
What's new:
• Full NEC Chapter 9 Table 4 coverage — 13 conduit types, including FMC, ENT, LFMC, LFNC-A/B, PVC Type A, PVC Type EB and HDPE
• More wire insulation types: XHHW-2, THW, RHH/RHW-2, USE-2 and TW
• Trade sizes now range from 3/8"
◆
Version 1.1.7 released
What's new:
• Moved to tradetools.dev — new umbrella site for all our trade calculators
• Updated support email: support@tradetools.dev
• Refreshed privacy & support pages with unified design
• Bug fixes and stability improvements
Thanks f
◆
Version 1.1.6 released
Privacy & ad consent update:
- Updated ad consent flow to comply with Google AdMob's latest privacy requirements
- Added "Manage Ad Privacy" option in Settings so users in the EU and UK can review or change their consent at any time
- Impr
◆
Version 1.1.5 released
Cross-promotion improvements: links to other Electools apps now open in App Store on iOS instead of Google Play.
Bug fixes and stability improvements.
◆
Version 1.1.4 released
AIen-GB
BNen-GB
BWen-GB
CLes-MX
CNzh-Hans-CN
COes-MX
CYen-GB
DEde-DE
ECes-MX
ESes-ES
FRfr-FR
HKzh-Hant-HK
JPja
KEen-GB
KYen-GB
LCen-GB
MDen-GB
MEen-GB
MOzh-Hant-HK
MTen-GB
MUen-GB
MYen-GB
PEes-MX
PYes-MX
TWzh-Hant-TW
USen-US
VCen-GB
VEes-MX
XKen-GB